Air Barriers: Impermeable or Permeable?

Words: Bronzella Cleveland

By Jane Wu

Air infiltration of buildings causes significant heating/cooling energy loss and permits moisture and condensation to collect in the walls. This interstitial condensation creates significant problems for buildings and occupants alike, including poor air quality, mold and mildew, and even structural damage.

To prevent these destructive outcomes, no building design today is complete without a continuous air barrier. However, architects and engineers are faced with the challenge of selecting an air barrier from the many types available, including the choice between vapor permeable and vapor impermeable air barriers.

Understanding vapor drive

Moisture vapor naturally diffuses into and through wall structures – a phenomenon called “vapor drive.” The degree of vapor drive is controlled by the porosity of the wall, together with environmental factors, especially moisture and temperature gradients. Moisture vapor will naturally move from a high concentration to a lower concentration and from the warm side to the cooler side. The greater the difference of the moisture gradient and temperature gradients, the greater the vapor drive.

What this means is that vapor drive will act differently, relative to a wall, depending on the climate, or even the time of year. Consider the simplified climate map below.

Diffusion versus condensation

Temperature and moisture gradients also are the key factors driving condensation. As moist, warm air moves across a falling temperature gradient, it cools. When the air reaches its dew point – the temperature at which it can no longer hold water – condensation occurs on the surface bordering the temperature gradients.

In most wall structures, the temperature gradient is greatest across the insulation layer. As warm, moist air on one side contacts the cool or cold, dry air on the other side, vapor condenses – right inside the wall cavity.

On the other hand, under certain circumstances, some degree of vapor diffusion actually may help keep wall cavities dry, by allowing any trapped moisture to escape the same way it got in.

So, while an air barrier is intended to prevent air leakage through a wall, care must be taken to ensure it also helps minimize the chances for condensation in the wall cavity.

Modeling vapor drive

Determining whether to use a vapor permeable or vapor impermeable air barrier – and how to use it – depends on a couple of key factors:

  • Climate: Where the wall is located
  • Wall Design: Where the air barrier and the insulation layer are located in relation to each other in the wall; what type of cladding is used. When solar radiation heats the highly absorptive cladding, such as brick veneer and manufactured masonry veneer units, following rain, elevated vapor pressures occur and induce inward water vapor flow through the building wall.

To understand how climatic changes interact with specific wall structure designs, a good modeling tool like Grace’s Perm-A-View exterior wall design modeling service can be invaluable. The Perm-A-View analysis is a dynamic simulation of heat and moisture transport through a multi-layer exterior wall exposed to natural weather. The Perm-A-View output is a complete report quantifying the potential for organic (mold) growth on moisture-sensitive wall components and potential for corrosion on corrosive materials. The report also identifies how much energy would be required to maintain the specified interior temperature during a one-year period.

Air infiltration of buildings causes significant heating/cooling energy loss and permits moisture and condensation to collect in the walls

Other important considerations

For any air barrier to be effective in preventing air leakage, it must be continuous as vapor drive can find even the smallest gaps in protection. For this reason, using high-quality flashing systems at all openings is crucial to ensure a continuous air barrier throughout the building envelope.

In addition, the air barrier should be firmly adhered to the wall surface. This is especially critical in wall designs with an air space between the air barrier and the exterior cladding. In these designs, wrap-type air barriers can “billow” to pump air back into buildings or at fastening points, causing it to stretch or potentially tear at anchor points when negative wind loads are strong enough, in effect “inflating” the air barrier envelope. Once breached, the air barrier loses its effectiveness.

The prime choices for a firmly adhered air barrier are self-adhered membranes and fluid-applied membranes. Both are available in vapor permeable or impermeable variations, and both can deliver equivalent performance.

Maintaining optimum dry film thickness of a fluid-applied membrane is critical to its performance. The thickness must be sufficient to cover all high and low points of the substrate. If the layer is too thin, voids can occur, creating leaks.

The value of professional guidance

Both vapor permeable and vapor impermeable air barriers play critical roles in modern wall design. The choice of product is dependent on a wide range of factors, including climate, wall design and other building components. In addition, building materials continually are advancing, presenting architects with new choices, each with its own pros and cons. Working with a professional or manufacturer who has both the technical expertise and the modeling tools to fully evaluate your design against real-world conditions can save you time during the design phase and headaches down the road.

Jane Wu is marketing manager, commercial air barrier products, at Grace Construction Products. She can be reached at chun-jen.wu@grace.com. For more information, visit www.graceconstruction.com. This article was previously published in the March 2012 issue of Metal Architecture magazine.

Save

The Importance of Instructor Support
April 2026

Whether you are a new or veteran masonry instructor, we all need support throughout our careers. We can never stop learning, and keeping up with ever-changing technology, materials, and installation techniques can be overwhelming alongside the everyday pr

Vibing Masonry #11: Innovative Concrete Masonry Technologies in Healthcare Design
April 2026

In the high-stakes environment of healthcare design, every material choice is a clinical decision. Architects, engineers, and facility administrators are tasked with creating spaces that are not only resilient and code-compliant but also conducive to heal

Why Termination Bars Still Matter: A Practical Look at Long‑Term Flashing Performance
April 2026

In recent discussions across the masonry industry, I have heard termination bars described as “old school.” The implication is that with modern materials, primerless peel-and-stick flashings, advanced sealants, and structural insulated sheathing, mechanic

Building Solutions: The Critical Role of Cavity Space in Masonry Moisture Control
April 2026

Long before “rainscreen” became a popular term in building science, masonry cavity walls were functioning on that very principle. A brick veneer cavity wall is designed with the expectation that water will penetrate the exterior