CMU Horizontal Wire Reinforcing

A grass roots effort is under way to modernize the way CMU horizontal wire reinforcing is manufactured, packaged, shipped and installed in North America. These changes, if implemented, will greatly enhance bricklayer productivity by optimizing lapping and narrowing the profile (height) where the pintles are welded to the wire.

For decades masons have been rightfully complaining about using truss wire in reinforced CMU and the difficulty of using lap welded adjustable wire reinforcing in CMU back-ups. As most CMU today is vertically reinforced the urgency to upgrade has reached the critical stage. Truss wire creates a problem when diagonal cross wires obstruct the core, interfering with the placement of vertical reinforcing, making it nearly impossible to meet minimum grouting standards. Ladder wire with 16" o.c. (on center) cross rods placed on the webs of the CMU keeps the core clear of obstructions that could restrict the placement of vertical reinforcing or the flow of grout.

Presently, two out of three manufacturers' produce standard 10'- 8" length wire with cross rods spaced 16" o.c. starting 8" off each end (Figure A). The third produces 16" o.c. wire by special order only. They continue to produce the majority of their wire 10' - 0" under the old standard with cross rods spaced 15" o.c. This is unfortunate because 15" o.c. makes it impossible for the mason to line up the cross rods on the webs of the CMU, again, making it difficult to ensure vertical core clearance for rebar and grout installation.

Figure A

STANDARD 2-WIRE
Produced by 2 of 3 manufacturers

Figure A
Advantages: CMU core clearance
Disadvantages:
  • Difficult to lap and meet standard
  • Heavy and bulky bundles are difficult to lift
  • Additional shipping and storage space required
  • Difficult to meet CMU heights
  • Detracts from bricklayer productivity
  • Masonry Reinforcing Corporation of America (MRCA) should be applauded for the giant leap they took in the winter of 98 to make the initial conversion with Dur-O-Wal following last winter. But many improvements remain before we start back slapping. The 16" o.c. cross rods are optimum for grouting but the 8" distance of the first cross rod off each end makes it difficult to lap the wire to meet the 6" minimum standard and maintain core clearance. The cross rods at the laps are within 8" of each other and this often results in an overlap instead of a side lap. Wire manufactured 10' - 0" long with cross rods 12" from each end and 16" o.c. would eliminate the risk of overlap by optimizing cross rod spacing on the webs of the CMU (Figure B). The best part about making these changes is that they don't need any approval. In fact, these changes will bring these materials closer to the design intent and installation criteria of architects', engineers' and mason contractors'.

    Figure B

    STANDARD 2-WIRE (Proposed)

    Figure B
    Advantages:
  • Optimum CMU core clearance
  • Simple to lap and meet standards
  • Lighter (approx. 4%) and less bulky (8") bundles
  • Requires less shipping and storage space
  • Lowers production costs by eliminating one cross rod and two welds
  • Improves bricklayer productivity by simplifying wire installation/laps
  • Makes masonry more competitive
  • Disadvantages: None

    MRCA and Dur-O-Wal produce adjustable hook & eye wire with the side rods starting 8" from each end with 3/16" dia. pintle eyes lap-welded on the top of the wire at the cross rods (Figure C). Hohmann & Barnard produces hook & eye with cross rods spaced approximately 15" o.c. with 3/16" dia. pintles welded 16" o.c. on the outer longitudinal wire. Pintles lap welded on top of the wire compounds the difficulty of installation, making it impossible for the bricklayer to meet the 6" lap standard or to maintain modular wall heights. Flush-welding pintles to the outer face of the proposed 16" o.c. 2-wire will narrow the wire profile (Figure D), overcoming the disadvantages of the present standard and significantly improving bricklayer productivity.

    Figure C

    STANDARD HOOK & EYE
    Produced by 2 of 3 manufacturers

    Figure C
    Advantages: CMU core clearance
    Disadvantages:
  • Extremely difficult to lap and meet standard
  • Very heavy and bulky bundles are difficult to lift
  • Additional shipping and storage space required
  • Very difficult to meet CMU heights, impossible at the laps
  • Significantly detracts from bricklayer productivity
  • At the time of this writing the three major wire manufacturers have been slow to recognize the changing landscape of CMU construction. The days of truss wire, 15" o.c. ladder, and lap-welded adjustable wire are fading. Although they haven't yet dedicated production capacity to producing these new ladder systems they all claim to have stepped up research and development and plan to meet demand when it reaches a practical volume. There is no doubt that a bold move by any one of these producers would soon become the industry standard for adjustable and 2-wire reinforcing as the advantages of these configurations would reach every facet of our industry.

    Mason contractors benefit from these two changes with wire that easily meets industry lapping standards, simplifies rebar installation and improves gout flow. Narrowing the profile of adjustable wire will improve bricklayer productivity by up to 15%, with less time installing the wire itself and improving their ability to meet modular heights. Contractors can reduce worker's compensation risk with shorter wire bundles (with one less cross rod and one less and shorter pintle eyes) that are lighter and easier to handle.

    In addition to the workers compensation issue, masonry distributors will gain with yard storage and shipping capacity. Both changes will result in bundles that are at least 8" shorter while flush-welded eyes narrow 250 lf bundles by two inches. Yard capacity requirements can be reduced and shipping capacity on trucks can be increased by 25-30%. This change will improve truckload stability by eliminating the spring in bundles.

    Manufacturers gain for all of the same reasons as mason contractors and distributors, with the additional benefit of lowering their production, packaging, and shipping costs. In addition, this system standardizes pintle packaging to match the quantities of all of their adjustable wire configurations.

    Figure D

    STANDARD HOOK & EYE (Proposed)

    Figure D
    Advantages:
  • Optimum CMU core clearance
  • Very simple to lap and meet standards
  • Easier to handle lighter and less bulky bundles
  • Reduce weight by 15% (less one cross rod & pintle w/shorter eye)
  • Reduce length by 8"
  • Reduce width of 250 lf bundle by up to 2"
  • Reduce weight of pintle boxes by 12.5%
  • Reduce risk of workers compensation claims
  • Improve wire installation time by 25% (less spring)
  • Improve CMU production by up to 15% w/narrower profile
  • Standardize bundle and pintle packaging (25 to 50 and 175 pintles)
  • Reduce bundle packaging time (tighter bundles w/4" less strapping)
  • Improve truckload stability by eliminating the spring in bundles
  • Increase load capacity of truckloads by up to 25-30%
  • Lower production, packaging, shipping, handling and installation costs
  • Makes a significant contribution to the competitiveness of masonry
  • Disadvantages: None

    So, you ask, what's taking so long? In short, the manufacturers have failed to recognize the fact that most wire reinforcing is not lapped according to the standards, in fact, most wire is butted end-to-end or if it is lapped it is likely causing the restrictions described above. The initial cost to upgrade the production equipment could be recaptured in a relatively short period with the savings from lower production, packaging and shipping costs described above.

    The time has come for bricklayers, mason contractors, block producers, distributors, architects and engineers to encourage wire producers to make these changes. We will all benefit from a product that significantly improves the effectiveness and competitiveness of masonry.

    Dur-O-Wal, Inc. 1-800-323-0090
    Hohmann & Barnard, Inc. 1-800-645-0616
    Masonry Reinforcing Corporation of America, Inc.
    1-800-849-6722


    Kyle Lochonic is a Project Manager for Davenport Masonry, Inc. in Holt, Michigan (517) 699-4279 and Jeff Snyder is the owner of Masonpro, Inc. in Northville, Michigan (800) 659-4731.






  •  
     

    www.masonrymagazine.com

    MASONRY
    ©2002 by the Mason Contractors Association of America
    All rights reserved
    33 South Roselle Road, Schaumburg, IL 60193
    Phone: 847-301-0001 or 800-536-2225 | Fax: 847-301-1110

    Web site by: Lionheart Publishing, Inc.
    506 Roswell Street, Suite 220, Marietta, GA 30060
    Phone: 770-431-0867 | Fax: 770-432-6969
    lpi@lionhrtpub.com
    www.lionhrtpub.com